{"id":9522,"date":"2024-12-06T14:51:33","date_gmt":"2024-12-06T13:51:33","guid":{"rendered":"https:\/\/irg-net.com\/?p=9522"},"modified":"2024-12-06T14:51:35","modified_gmt":"2024-12-06T13:51:35","slug":"upgrade-dell-ome-from-3-10-x-to-4-0","status":"publish","type":"post","link":"https:\/\/irg-net.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/","title":{"rendered":"Upgrade Dell OME from 3.10.x to 4.0"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"647\" height=\"274\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-3.png?resize=647%2C274&#038;ssl=1\" alt=\"\" class=\"wp-image-9523\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-3.png?w=647&amp;ssl=1 647w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-3.png?resize=300%2C127&amp;ssl=1 300w\" sizes=\"auto, (max-width: 647px) 100vw, 647px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The latest version of <strong>Dell OpenManage Enterprise 4.0<\/strong> was released on October 30, 2023. Some customers are already using the 4.0 version and are giving generally positive feedback, especially regarding performance. That&#8217;s why I would like to describe the <strong>upgrade path from 3.10.x to 4.0<\/strong> in this blog post.<\/p>\n\n\n\n<p>Before we start, I want to give you some basic upgrade paths, because you can only upgrade directly from 3.10.x to 4.0. If you are on an older release, you will need to upgrade in between.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"128\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2022\/07\/Dell_Technologies_logo.svg_.png?resize=1024%2C128&#038;ssl=1\" alt=\"\" class=\"wp-image-1586\" style=\"width:424px;height:auto\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2022\/07\/Dell_Technologies_logo.svg_.png?resize=1024%2C128&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2022\/07\/Dell_Technologies_logo.svg_.png?resize=300%2C38&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2022\/07\/Dell_Technologies_logo.svg_.png?resize=768%2C96&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2022\/07\/Dell_Technologies_logo.svg_.png?resize=1536%2C192&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2022\/07\/Dell_Technologies_logo.svg_.png?resize=2048%2C256&amp;ssl=1 2048w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2022\/07\/Dell_Technologies_logo.svg_.png?w=2280&amp;ssl=1 2280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Upgrade from any previous version to OpenManage Enterprise 3.10.<\/strong><\/p>\n\n\n\n<p>Upgrading to OpenManage Enterprise 3.10 directly from OpenManage Enterprise 3.9, 3.8.x, 3.7.x, 3.6.x, 3.5.x, 3.4.x, 3.3.x, 3.2.x, OpenManage Enterprise 3.1, OpenManage Enterprise 3.0, or OpenManage Enterprise Tech Release (1.0) directly is not supported.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li style=\"font-size:15px\">Upgrade from OpenManage Enterprise 3.9 but first upgrade to version 3.9.2 before considering an upgrade to 3.10.\n<ul class=\"wp-block-list\">\n<li>3.9-&gt;3.9.2-&gt;3.10<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li style=\"font-size:15px\">OpenManage Enterprise versions 3.7.x or 3.8.x must first be upgraded to version 3.9, then to 3.9.2, before considering an upgrade to 3.10.\n<ul class=\"wp-block-list\">\n<li>3.7.x-&gt;3.9-&gt;3.9.2-&gt;3.10<\/li>\n\n\n\n<li>3.8.x-&gt;3.9-&gt;3.9.2-&gt;3.10<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li style=\"font-size:15px\">OpenManage Enterprise versions earlier than versions 3.7 must first be updated to version 3.9, then to 3.9.2, before considering an upgrade to 3.10.\n<ul class=\"wp-block-list\">\n<li>3.6.x-&gt;3.8-&gt;3.9-&gt;3.9.2-&gt;3.10<\/li>\n\n\n\n<li>3.5.x-&gt;3.7-&gt;3.9-&gt;3.9.2-&gt;3.10<\/li>\n\n\n\n<li>3.4.x-&gt;3.6.1-&gt;3.8-&gt;3.9-&gt;3.9.2-&gt;3.10<\/li>\n\n\n\n<li>3.3.x-&gt;3.5-&gt;3.7-&gt;3.9-&gt;3.9.2-&gt;3.10<\/li>\n\n\n\n<li>3.2.x-&gt;3.4-&gt;3.6.1-&gt;3.8-&gt;3.9-&gt;3.9.2-&gt;3.10<\/li>\n\n\n\n<li>3.1.x-&gt;3.3.1-&gt;3.5-&gt;3.7-&gt;3.9-&gt;3.9.2-&gt;3.10<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p>OpenManage Enterprise &#8211; Tech Release version should be first upgraded to OpenManage Enterprise version 3.1.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"879\" height=\"253\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/DT_TitaniumBlackPartner_Blue.png?resize=879%2C253&#038;ssl=1\" alt=\"\" class=\"wp-image-9535\" style=\"width:403px;height:auto\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/DT_TitaniumBlackPartner_Blue.png?w=879&amp;ssl=1 879w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/DT_TitaniumBlackPartner_Blue.png?resize=300%2C86&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/DT_TitaniumBlackPartner_Blue.png?resize=768%2C221&amp;ssl=1 768w\" sizes=\"auto, (max-width: 879px) 100vw, 879px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Unlike previous versions, <strong>OME 4.0 does not offer an in-place upgrade from 3.10.x<\/strong>, but rather a transfer of existing data to a new instance of the appliance. Basically, there are 3 tasks for a successful upgrade:<\/p>\n\n\n\n<ol id=\"isPasted\" class=\"wp-block-list\">\n<li style=\"font-size:15px\">Deploy a new instance of OME 4.0 virtual appliance (VMware, Hyper-V or KVM)<\/li>\n\n\n\n<li style=\"font-size:15px\">Migrate data from OME 3.10.x to OME 4.0<\/li>\n\n\n\n<li style=\"font-size:15px\">Decommission old OME 3.10.x virtual appliance<\/li>\n<\/ol>\n\n\n\n<p>Allright let&#8217;s start with the Deployment of OME 4.0 in our VMware vSphere environment:<\/p>\n\n\n\n<p>Hier kommen die OVA deployment bilder rein<\/p>\n\n\n\n<p>After that open the virtual console of the freshly deployed appliance and <strong>change the Admin Password<\/strong>, set the <strong>Appliance Hostname<\/strong> and <strong>Networking Parameters<\/strong> so the OME 4.0 appliance can reach the OME 3.10 appliance. <\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"755\" height=\"552\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-25.png?resize=755%2C552&#038;ssl=1\" alt=\"\" class=\"wp-image-9697\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-25.png?w=755&amp;ssl=1 755w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-25.png?resize=300%2C219&amp;ssl=1 300w\" sizes=\"auto, (max-width: 755px) 100vw, 755px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-center has-text-color has-link-color wp-elements-1355441eb1899262389f43fce5886553\" style=\"color:#ff0000\"><strong>!!! If you disable IPv6 in Networking Parameters; you have to reboot the appliance !!!<\/strong><\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"555\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-26.png?resize=750%2C555&#038;ssl=1\" alt=\"\" class=\"wp-image-9698\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-26.png?w=750&amp;ssl=1 750w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-26.png?resize=300%2C222&amp;ssl=1 300w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>As soon as the appliance is available again, we log in via the browser using FQDN or IP.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"761\" height=\"899\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-27.png?resize=761%2C899&#038;ssl=1\" alt=\"\" class=\"wp-image-9699\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-27.png?w=761&amp;ssl=1 761w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-27.png?resize=254%2C300&amp;ssl=1 254w\" sizes=\"auto, (max-width: 761px) 100vw, 761px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>You will be asked if you want to use the <strong>iDRAC password rotation<\/strong> feature in OME 4.0, in my upgrade scenario I will not enable it, what exactly happens you can read in the screenshot:<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"921\" height=\"321\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-28.png?resize=921%2C321&#038;ssl=1\" alt=\"\" class=\"wp-image-9700\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-28.png?w=921&amp;ssl=1 921w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-28.png?resize=300%2C105&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-28.png?resize=768%2C268&amp;ssl=1 768w\" sizes=\"auto, (max-width: 921px) 100vw, 921px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>After clicking <strong>Next<\/strong>, you will get two options: a <strong>migration <\/strong>or a <strong>new deployment of OME 4.0<\/strong>, as we want to migrate, I select this option:<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"911\" height=\"269\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-29.png?resize=911%2C269&#038;ssl=1\" alt=\"\" class=\"wp-image-9701\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-29.png?w=911&amp;ssl=1 911w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-29.png?resize=300%2C89&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-29.png?resize=768%2C227&amp;ssl=1 768w\" sizes=\"auto, (max-width: 911px) 100vw, 911px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>After you click on <strong>Finish<\/strong>, OME automatically switches to the <strong>Backup \/ Restore<\/strong> tab and then to <strong>Migrate In<\/strong>. The information from the source system is now required here, i.e. our OME 3.10 appliance:<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"533\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-30.png?resize=1024%2C533&#038;ssl=1\" alt=\"\" class=\"wp-image-9702\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-30.png?resize=1024%2C533&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-30.png?resize=300%2C156&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-30.png?resize=768%2C400&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-30.png?w=1034&amp;ssl=1 1034w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>We can answer Step 1 straight away, but of course it depends on your customer situation. In my case, I will continue with <strong>self-signed certificates<\/strong>. Otherwise you will have to upload the appropriate certificate:<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"518\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-31.png?resize=1024%2C518&#038;ssl=1\" alt=\"\" class=\"wp-image-9703\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-31.png?resize=1024%2C518&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-31.png?resize=300%2C152&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-31.png?resize=768%2C388&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-31.png?w=1036&amp;ssl=1 1036w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>In step 2, the connection data to the source system is also required:<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"924\" height=\"745\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-32.png?resize=924%2C745&#038;ssl=1\" alt=\"\" class=\"wp-image-9704\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-32.png?w=924&amp;ssl=1 924w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-32.png?resize=300%2C242&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-32.png?resize=768%2C619&amp;ssl=1 768w\" sizes=\"auto, (max-width: 924px) 100vw, 924px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>As soon as we have entered and validated the credentials from the source system, the OME 4.0 appliance switches to import mode, i.e. it expects the data from the source system.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"919\" height=\"453\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-34.png?resize=919%2C453&#038;ssl=1\" alt=\"\" class=\"wp-image-9706\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-34.png?w=919&amp;ssl=1 919w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-34.png?resize=300%2C148&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-34.png?resize=768%2C379&amp;ssl=1 768w\" sizes=\"auto, (max-width: 919px) 100vw, 919px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Now, let&#8217;s switch to our OME 3.10 appliance and go to <strong>Backup\/Restore<\/strong>, <strong>Migrate<\/strong>, and then <strong>Migrate Out<\/strong>. Again, there are a few steps that need to be completed. Starting with the certificates:<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-33.png?resize=1024%2C572&#038;ssl=1\" alt=\"\" class=\"wp-image-9705\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-33.png?resize=1024%2C572&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-33.png?resize=300%2C168&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-33.png?resize=768%2C429&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-33.png?w=1028&amp;ssl=1 1028w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>We then ensure the access to the target system:<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"785\" height=\"521\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-34.png?resize=785%2C521&#038;ssl=1\" alt=\"\" class=\"wp-image-11608\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-34.png?w=785&amp;ssl=1 785w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-34.png?resize=300%2C199&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-34.png?resize=768%2C510&amp;ssl=1 768w\" sizes=\"auto, (max-width: 785px) 100vw, 785px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Next, click on the Red Bar for more details and you will see the OME Readiness Report is ongoing:<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"650\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-35.png?resize=1024%2C650&#038;ssl=1\" alt=\"\" class=\"wp-image-11609\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-35.png?resize=1024%2C650&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-35.png?resize=300%2C190&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-35.png?resize=768%2C487&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-35.png?w=1365&amp;ssl=1 1365w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>You can then run the import task on the new 4.0 OME appliance:<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"992\" height=\"767\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-36.png?resize=992%2C767&#038;ssl=1\" alt=\"\" class=\"wp-image-11610\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-36.png?w=992&amp;ssl=1 992w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-36.png?resize=300%2C232&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-36.png?resize=768%2C594&amp;ssl=1 768w\" sizes=\"auto, (max-width: 992px) 100vw, 992px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Of course, agreements and notices must be read and accepted in order to initiate the import operation:<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"754\" height=\"482\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-37.png?resize=754%2C482&#038;ssl=1\" alt=\"\" class=\"wp-image-11611\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-37.png?w=754&amp;ssl=1 754w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-37.png?resize=300%2C192&amp;ssl=1 300w\" sizes=\"auto, (max-width: 754px) 100vw, 754px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Then it&#8217;s time for a coffee \ud83d\ude09 After the import, all data should be transferred from the old OME to the new one.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"706\" height=\"387\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-39.png?resize=706%2C387&#038;ssl=1\" alt=\"\" class=\"wp-image-11613\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-39.png?w=706&amp;ssl=1 706w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-39.png?resize=300%2C164&amp;ssl=1 300w\" sizes=\"auto, (max-width: 706px) 100vw, 706px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"892\" height=\"245\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-40.png?resize=892%2C245&#038;ssl=1\" alt=\"\" class=\"wp-image-11614\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-40.png?w=892&amp;ssl=1 892w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-40.png?resize=300%2C82&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-40.png?resize=768%2C211&amp;ssl=1 768w\" sizes=\"auto, (max-width: 892px) 100vw, 892px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"767\" height=\"202\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-41.png?resize=767%2C202&#038;ssl=1\" alt=\"\" class=\"wp-image-11615\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-41.png?w=767&amp;ssl=1 767w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/07\/image-41.png?resize=300%2C79&amp;ssl=1 300w\" sizes=\"auto, (max-width: 767px) 100vw, 767px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Migration is only required if you are upgrading from OME 3.10.x (CentOS-based) to OME 4.0 (SLES-based). In the future, <strong>in-place upgrades will be supported<\/strong> when upgrading (for example, from OME 4.0 to OME 4.1).<\/p>\n\n\n\n<p>This transfer of existing OME data, such as discovered servers, deployment templates, policies, logs, and credentials, is accomplished through the migration feature built into OME. This migration wizard provides a step-by-step process to export data from the OME 3.10.x appliance and import it into a fresh OME 4.0 appliance. To migrate, you must have OME 4.0 installed and configured with a new IP address and administrator account. In addition, the existing OME 3.10.x and new OME 4.0 instances must be able to communicate over the network.<\/p>\n\n\n\n<p>Sources: <a href=\"https:\/\/www.dell.com\/support\/kbdoc\/en-us\/000175879\/support-for-openmanage-enterprise#OME-Download\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.dell.com\/support\/kbdoc\/en-us\/000175879\/support-for-openmanage-enterprise#OME-Download<\/a><br><a href=\"https:\/\/infohub.delltechnologies.com\/en-US\/p\/upgrading-to-openmanage-enterprise-4-0\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/infohub.delltechnologies.com\/en-US\/p\/upgrading-to-openmanage-enterprise-4-0\/<\/a><\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>This is it from this Blog Post, if you have any questions please use the comment section below. \ud83d\ude42<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The latest version of Dell OpenManage Enterprise 4.0 was released on October 30, 2023. Some customers are already using the 4.0 version and are giving generally positive feedback, especially regarding performance. That&#8217;s why I would like to describe the upgrade path from 3.10.x to 4.0 in this blog post. Before we start, I want to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":true,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[1,18,54],"tags":[],"class_list":["post-9522","post","type-post","status-publish","format-standard","hentry","category-blog","category-dellemc","category-dell-openmanage-enterprise"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Upgrade Dell OME from 3.10.x to 4.0 - irgNET<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Upgrade Dell OME from 3.10.x to 4.0 - irgNET\" \/>\n<meta property=\"og:description\" content=\"The latest version of Dell OpenManage Enterprise 4.0 was released on October 30, 2023. Some customers are already using the 4.0 version and are giving generally positive feedback, especially regarding performance. That&#8217;s why I would like to describe the upgrade path from 3.10.x to 4.0 in this blog post. Before we start, I want to [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/\" \/>\n<meta property=\"og:site_name\" content=\"irgNET\" \/>\n<meta property=\"article:published_time\" content=\"2024-12-06T13:51:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-06T13:51:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/wp-content\/uploads\/2024\/02\/image-3.png\" \/>\n<meta name=\"author\" content=\"H. Cemre G\u00fcnay\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@irg_net\" \/>\n<meta name=\"twitter:site\" content=\"@irg_net\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"H. Cemre G\u00fcnay\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/\"},\"author\":{\"name\":\"H. Cemre G\u00fcnay\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#\\\/schema\\\/person\\\/71b46e79e8c12bdc8e610214a6621a66\"},\"headline\":\"Upgrade Dell OME from 3.10.x to 4.0\",\"datePublished\":\"2024-12-06T13:51:33+00:00\",\"dateModified\":\"2024-12-06T13:51:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/\"},\"wordCount\":838,\"commentCount\":1,\"publisher\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/image-3.png\",\"articleSection\":[\"Blog\",\"Dell\",\"Dell OpenManage Enterprise\"],\"inLanguage\":\"en\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/\",\"url\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/\",\"name\":\"Upgrade Dell OME from 3.10.x to 4.0 - irgNET\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/image-3.png\",\"datePublished\":\"2024-12-06T13:51:33+00:00\",\"dateModified\":\"2024-12-06T13:51:35+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/#breadcrumb\"},\"inLanguage\":\"en\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/#primaryimage\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/image-3.png?fit=647%2C274&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/image-3.png?fit=647%2C274&ssl=1\",\"width\":647,\"height\":274},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/upgrade-dell-ome-from-3-10-x-to-4-0\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Upgrade Dell OME from 3.10.x to 4.0\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#website\",\"url\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/\",\"name\":\"irgNET\",\"description\":\"a virtual Knowledge Base\",\"publisher\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#organization\",\"name\":\"irg-NET\",\"url\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/i2.wp.com\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2021\\\/06\\\/cropped-FINAL-Removed-Alpha.png?fit=2048%2C2048&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i2.wp.com\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2021\\\/06\\\/cropped-FINAL-Removed-Alpha.png?fit=2048%2C2048&ssl=1\",\"width\":2048,\"height\":2048,\"caption\":\"irg-NET\"},\"image\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/irg_net\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/h-cemre-g\u00fcnay-2b61601b4\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UC8GknhO5YMAkAoVxppu6aaQ\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#\\\/schema\\\/person\\\/71b46e79e8c12bdc8e610214a6621a66\",\"name\":\"H. Cemre G\u00fcnay\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g\",\"caption\":\"H. Cemre G\u00fcnay\"},\"sameAs\":[\"http:\\\/\\\/192.168.34.155\\\/wordpress\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Upgrade Dell OME from 3.10.x to 4.0 - irgNET","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/","og_locale":"en_US","og_type":"article","og_title":"Upgrade Dell OME from 3.10.x to 4.0 - irgNET","og_description":"The latest version of Dell OpenManage Enterprise 4.0 was released on October 30, 2023. Some customers are already using the 4.0 version and are giving generally positive feedback, especially regarding performance. That&#8217;s why I would like to describe the upgrade path from 3.10.x to 4.0 in this blog post. Before we start, I want to [&hellip;]","og_url":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/","og_site_name":"irgNET","article_published_time":"2024-12-06T13:51:33+00:00","article_modified_time":"2024-12-06T13:51:35+00:00","og_image":[{"url":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/wp-content\/uploads\/2024\/02\/image-3.png","type":"","width":"","height":""}],"author":"H. Cemre G\u00fcnay","twitter_card":"summary_large_image","twitter_creator":"@irg_net","twitter_site":"@irg_net","twitter_misc":{"Written by":"H. Cemre G\u00fcnay","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/#article","isPartOf":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/"},"author":{"name":"H. Cemre G\u00fcnay","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#\/schema\/person\/71b46e79e8c12bdc8e610214a6621a66"},"headline":"Upgrade Dell OME from 3.10.x to 4.0","datePublished":"2024-12-06T13:51:33+00:00","dateModified":"2024-12-06T13:51:35+00:00","mainEntityOfPage":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/"},"wordCount":838,"commentCount":1,"publisher":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#organization"},"image":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/#primaryimage"},"thumbnailUrl":"https:\/\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-3.png","articleSection":["Blog","Dell","Dell OpenManage Enterprise"],"inLanguage":"en","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/","url":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/","name":"Upgrade Dell OME from 3.10.x to 4.0 - irgNET","isPartOf":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/#primaryimage"},"image":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/#primaryimage"},"thumbnailUrl":"https:\/\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-3.png","datePublished":"2024-12-06T13:51:33+00:00","dateModified":"2024-12-06T13:51:35+00:00","breadcrumb":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/#breadcrumb"},"inLanguage":"en","potentialAction":[{"@type":"ReadAction","target":["https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/"]}]},{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/#primaryimage","url":"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-3.png?fit=647%2C274&ssl=1","contentUrl":"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/02\/image-3.png?fit=647%2C274&ssl=1","width":647,"height":274},{"@type":"BreadcrumbList","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/upgrade-dell-ome-from-3-10-x-to-4-0\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/"},{"@type":"ListItem","position":2,"name":"Upgrade Dell OME from 3.10.x to 4.0"}]},{"@type":"WebSite","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#website","url":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/","name":"irgNET","description":"a virtual Knowledge Base","publisher":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en"},{"@type":"Organization","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#organization","name":"irg-NET","url":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/","logo":{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#\/schema\/logo\/image\/","url":"https:\/\/i2.wp.com\/irg-net.com\/wp-content\/uploads\/2021\/06\/cropped-FINAL-Removed-Alpha.png?fit=2048%2C2048&ssl=1","contentUrl":"https:\/\/i2.wp.com\/irg-net.com\/wp-content\/uploads\/2021\/06\/cropped-FINAL-Removed-Alpha.png?fit=2048%2C2048&ssl=1","width":2048,"height":2048,"caption":"irg-NET"},"image":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/irg_net","https:\/\/www.linkedin.com\/in\/h-cemre-g\u00fcnay-2b61601b4\/","https:\/\/www.youtube.com\/channel\/UC8GknhO5YMAkAoVxppu6aaQ"]},{"@type":"Person","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#\/schema\/person\/71b46e79e8c12bdc8e610214a6621a66","name":"H. Cemre G\u00fcnay","image":{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/secure.gravatar.com\/avatar\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g","caption":"H. Cemre G\u00fcnay"},"sameAs":["http:\/\/192.168.34.155\/wordpress"]}]}},"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/posts\/9522","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/comments?post=9522"}],"version-history":[{"count":12,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/posts\/9522\/revisions"}],"predecessor-version":[{"id":12983,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/posts\/9522\/revisions\/12983"}],"wp:attachment":[{"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/media?parent=9522"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/categories?post=9522"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/tags?post=9522"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}