{"id":12438,"date":"2024-10-23T16:57:02","date_gmt":"2024-10-23T14:57:02","guid":{"rendered":"https:\/\/irg-net.com\/?p=12438"},"modified":"2024-10-23T17:04:51","modified_gmt":"2024-10-23T15:04:51","slug":"dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device","status":"publish","type":"post","link":"https:\/\/irg-net.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/","title":{"rendered":"Dell VxRail \/ vSphere 8.0.310 Update &#8211; Advisory Report identified issues with BOSS Device"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"304\" height=\"266\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2023\/07\/picture6.webp?resize=304%2C266&#038;ssl=1\" alt=\"\" class=\"wp-image-6034\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2023\/07\/picture6.webp?w=304&amp;ssl=1 304w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2023\/07\/picture6.webp?resize=300%2C263&amp;ssl=1 300w\" sizes=\"auto, (max-width: 304px) 100vw, 304px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>In a VxRail 8.0.300 deployment, I wanted to upgrade the appliance to the latest 8.0.310 after the initial cluster deployment, but I was confronted with a very strange phenomenon in the advisory report.<\/p>\n\n\n\n<p>Important details:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"font-size:15px\">the VxRail nodes are based on AMD<\/li>\n\n\n\n<li style=\"font-size:15px\">the nodes have been updated with the RASR process to 8.0.300<\/li>\n\n\n\n<li style=\"font-size:15px\">the cluster was deployed in LCM (legacy) not vLCM mode<\/li>\n<\/ul>\n\n\n\n<p>Normally, all components of a VxRail node are updated with the RASR or Update image to the version provided by the Image, e.g. 8.0.300. This time, however, I was confronted with an anomaly. In this blog post, I would like to show you how I solved the problem.<\/p>\n\n\n\n<p>So, the advisory report from the VxRail cluster shows that the update will not run successfully, if you dont fix the issues.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"530\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-21.png?resize=1024%2C530&#038;ssl=1\" alt=\"\" class=\"wp-image-12454\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-21.png?resize=1024%2C530&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-21.png?resize=300%2C155&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-21.png?resize=768%2C397&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-21.png?resize=1536%2C795&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-21.png?w=1778&amp;ssl=1 1778w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>If you open the report, you will see, among other things, that the approx. Installation Time is set to &#8220;<strong>&#8211; <\/strong>-&#8220;, i.e. the appliance cannot yet estimate whether and for how long the update will run.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"516\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-24.png?resize=1024%2C516&#038;ssl=1\" alt=\"\" class=\"wp-image-12457\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-24.png?resize=1024%2C516&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-24.png?resize=300%2C151&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-24.png?resize=768%2C387&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-24.png?resize=1536%2C775&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-24.png?w=1822&amp;ssl=1 1822w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>This vSAN Cluster has 6 Nodes and you can see 6 components under \u201c<strong>not ready for update<\/strong>\u201d. I have opened one of the VxRail nodes as an example and you can see that a certain component is the Dell BOSS device also known as Micron M.2 or similar, which prevents us from the Update. (Sorry for the blur under Component)<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"393\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-23.png?resize=1024%2C393&#038;ssl=1\" alt=\"\" class=\"wp-image-12456\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-23.png?resize=1024%2C393&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-23.png?resize=300%2C115&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-23.png?resize=768%2C295&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-23.png?resize=1536%2C589&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-23.png?resize=2048%2C786&amp;ssl=1 2048w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-23.png?w=2280&amp;ssl=1 2280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>So what now? It is expressly forbidden to update individual components of a VxRail appliance, this process must be carried out via the VxRail Manager in combination with the vCenter\u2026<\/p>\n\n\n\n<p>Lets contact the support, who suggested manually updating the BOSS device, in our case it was the firmware:<br><strong>Serial-ATA_Firmware_KT63Y_WN64_J008_A00.EXE<\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-7b06896cf3aab370cc25a72f32ebe7de\" style=\"color:#ff0000\"><strong>Important before you install individual firmware\/driver packages in a VxRail cluster: be sure to get the go-ahead from Dell Support and do not act on your own!<\/strong><\/p>\n\n\n\n<p>Upload the firmware file as usual from classic PowerEdge servers (without OpenManage Enterprise) in iDRAC and say &#8211; \u201c<strong>Install on next Reboot<\/strong>\u201d.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"440\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_154755.png?resize=1024%2C440&#038;ssl=1\" alt=\"\" class=\"wp-image-12451\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_154755.png?resize=1024%2C440&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_154755.png?resize=300%2C129&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_154755.png?resize=768%2C330&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_154755.png?resize=1536%2C661&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_154755.png?w=1616&amp;ssl=1 1616w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Then take a look at the Job Queue to see the message: \u201c<strong>Task successfully scheduled<\/strong>\u201d.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"324\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_154842.png?resize=1024%2C324&#038;ssl=1\" alt=\"\" class=\"wp-image-12448\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_154842.png?resize=1024%2C324&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_154842.png?resize=300%2C95&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_154842.png?resize=768%2C243&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_154842.png?w=1408&amp;ssl=1 1408w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>To install the firmware package, put the node into maintenance mode and restart it.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"333\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-22.png?resize=1024%2C333&#038;ssl=1\" alt=\"\" class=\"wp-image-12455\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-22.png?resize=1024%2C333&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-22.png?resize=300%2C98&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-22.png?resize=768%2C250&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-22.png?resize=1536%2C500&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-22.png?resize=2048%2C667&amp;ssl=1 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>After all nodes have installed and restarted their firmware packages, we go back to the update section and pull a new advisory report.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"575\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-26.png?resize=1024%2C575&#038;ssl=1\" alt=\"\" class=\"wp-image-12460\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-26.png?resize=1024%2C575&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-26.png?resize=300%2C168&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-26.png?resize=768%2C431&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-26.png?resize=1536%2C862&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-26.png?w=1666&amp;ssl=1 1666w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>This time we have an orange warning window, so let&#8217;s take a look before we start the update, of course:<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"523\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-25.png?resize=1024%2C523&#038;ssl=1\" alt=\"\" class=\"wp-image-12459\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-25.png?resize=1024%2C523&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-25.png?resize=300%2C153&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-25.png?resize=768%2C392&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-25.png?resize=1536%2C785&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-25.png?w=1697&amp;ssl=1 1697w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The individual components of the nodes are in an optimally state after the firmware installation.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"735\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-27.png?resize=1024%2C735&#038;ssl=1\" alt=\"\" class=\"wp-image-12461\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-27.png?resize=1024%2C735&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-27.png?resize=300%2C215&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-27.png?resize=768%2C552&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-27.png?resize=1536%2C1103&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-27.png?w=1579&amp;ssl=1 1579w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The cluster including nodes and the vCenter are doing well, but the VxRail Manager has something to report. Since it is an external vCenter, you get a warning with a suitable KB article to avoid possible version mismatches.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"546\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_184858.png?resize=1024%2C546&#038;ssl=1\" alt=\"\" class=\"wp-image-12439\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_184858.png?resize=1024%2C546&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_184858.png?resize=300%2C160&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_184858.png?resize=768%2C410&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_184858.png?w=1087&amp;ssl=1 1087w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"244\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_184920.png?resize=1024%2C244&#038;ssl=1\" alt=\"\" class=\"wp-image-12441\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_184920.png?resize=1024%2C244&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_184920.png?resize=300%2C71&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_184920.png?resize=768%2C183&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_184920.png?w=1101&amp;ssl=1 1101w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>I have attached a screenshot of the KB article here. It is important to know that the vCenter must always be on the same or a newer version as the VxRail. This should be checked before every update to avoid failures.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"707\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_185404.png?resize=1024%2C707&#038;ssl=1\" alt=\"\" class=\"wp-image-12442\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_185404.png?resize=1024%2C707&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_185404.png?resize=300%2C207&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_185404.png?resize=768%2C530&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/2024-10-21_185404.png?w=1521&amp;ssl=1 1521w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>So we return to the vCenter and first check whether the individual nodes are in a \u201c<strong>healthy<\/strong>\u201d state.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"279\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-38.png?resize=1024%2C279&#038;ssl=1\" alt=\"\" class=\"wp-image-12498\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-38.png?resize=1024%2C279&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-38.png?resize=300%2C82&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-38.png?resize=768%2C209&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-38.png?resize=1536%2C419&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-38.png?resize=2048%2C558&amp;ssl=1 2048w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-38.png?w=2280&amp;ssl=1 2280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Then we start the update process and lean back.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"378\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-39.png?resize=1024%2C378&#038;ssl=1\" alt=\"\" class=\"wp-image-12499\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-39.png?resize=1024%2C378&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-39.png?resize=300%2C111&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-39.png?resize=768%2C283&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-39.png?resize=1536%2C567&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-39.png?resize=2048%2C756&amp;ssl=1 2048w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-39.png?w=2280&amp;ssl=1 2280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>That&#8217;s it, the VxRail Cluster is up to date! If you have any questions, please use the comment section. \ud83d\ude42<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"317\" src=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-37.png?resize=1024%2C317&#038;ssl=1\" alt=\"\" class=\"wp-image-12497\" srcset=\"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-37.png?resize=1024%2C317&amp;ssl=1 1024w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-37.png?resize=300%2C93&amp;ssl=1 300w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-37.png?resize=768%2C238&amp;ssl=1 768w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-37.png?resize=1536%2C476&amp;ssl=1 1536w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-37.png?resize=2048%2C635&amp;ssl=1 2048w, https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2024\/10\/image-37.png?w=2280&amp;ssl=1 2280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-63d20f26dbe5f44566107479905cf325\" style=\"color:#ff000000\">ackages in a VxRail cluster: be sure  et the go-ahead from Dell Support and do not act on your own<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In a VxRail 8.0.300 deployment, I wanted to upgrade the appliance to the latest 8.0.310 after the initial cluster deployment, but I was confronted with a very strange phenomenon in the advisory report. Important details: Normally, all components of a VxRail node are updated with the RASR or Update image to the version provided by [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":true,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[1,18,48],"tags":[],"class_list":["post-12438","post","type-post","status-publish","format-standard","hentry","category-blog","category-dellemc","category-dell-vxrail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Dell VxRail \/ vSphere 8.0.310 Update - Advisory Report identified issues with BOSS Device - irgNET<\/title>\n<meta name=\"description\" content=\"In a VxRail 8.0.300 deployment, I wanted to upgrade the appliance to the latest 8.0.310 after the initial cluster deployment, but I was confronted with a very strange phenomenon in the advisory report.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Dell VxRail \/ vSphere 8.0.310 Update - Advisory Report identified issues with BOSS Device - irgNET\" \/>\n<meta property=\"og:description\" content=\"In a VxRail 8.0.300 deployment, I wanted to upgrade the appliance to the latest 8.0.310 after the initial cluster deployment, but I was confronted with a very strange phenomenon in the advisory report.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/\" \/>\n<meta property=\"og:site_name\" content=\"irgNET\" \/>\n<meta property=\"article:published_time\" content=\"2024-10-23T14:57:02+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-10-23T15:04:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/wp-content\/uploads\/2023\/07\/picture6.webp\" \/>\n<meta name=\"author\" content=\"H. Cemre G\u00fcnay\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@irg_net\" \/>\n<meta name=\"twitter:site\" content=\"@irg_net\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"H. Cemre G\u00fcnay\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/\"},\"author\":{\"name\":\"H. Cemre G\u00fcnay\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#\\\/schema\\\/person\\\/71b46e79e8c12bdc8e610214a6621a66\"},\"headline\":\"Dell VxRail \\\/ vSphere 8.0.310 Update &#8211; Advisory Report identified issues with BOSS Device\",\"datePublished\":\"2024-10-23T14:57:02+00:00\",\"dateModified\":\"2024-10-23T15:04:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/\"},\"wordCount\":577,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/picture6.webp\",\"articleSection\":[\"Blog\",\"Dell\",\"Dell VxRail\"],\"inLanguage\":\"en\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/\",\"url\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/\",\"name\":\"Dell VxRail \\\/ vSphere 8.0.310 Update - Advisory Report identified issues with BOSS Device - irgNET\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/picture6.webp\",\"datePublished\":\"2024-10-23T14:57:02+00:00\",\"dateModified\":\"2024-10-23T15:04:51+00:00\",\"description\":\"In a VxRail 8.0.300 deployment, I wanted to upgrade the appliance to the latest 8.0.310 after the initial cluster deployment, but I was confronted with a very strange phenomenon in the advisory report.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/#breadcrumb\"},\"inLanguage\":\"en\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/#primaryimage\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/picture6.webp?fit=304%2C266&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/picture6.webp?fit=304%2C266&ssl=1\",\"width\":304,\"height\":266},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/index.php\\\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Dell VxRail \\\/ vSphere 8.0.310 Update &#8211; Advisory Report identified issues with BOSS Device\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#website\",\"url\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/\",\"name\":\"irgNET\",\"description\":\"a virtual Knowledge Base\",\"publisher\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#organization\",\"name\":\"irg-NET\",\"url\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/i2.wp.com\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2021\\\/06\\\/cropped-FINAL-Removed-Alpha.png?fit=2048%2C2048&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i2.wp.com\\\/irg-net.com\\\/wp-content\\\/uploads\\\/2021\\\/06\\\/cropped-FINAL-Removed-Alpha.png?fit=2048%2C2048&ssl=1\",\"width\":2048,\"height\":2048,\"caption\":\"irg-NET\"},\"image\":{\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/irg_net\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/h-cemre-g\u00fcnay-2b61601b4\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UC8GknhO5YMAkAoVxppu6aaQ\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/irgnet-ga3w6nfbvw.live-website.com\\\/#\\\/schema\\\/person\\\/71b46e79e8c12bdc8e610214a6621a66\",\"name\":\"H. Cemre G\u00fcnay\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g\",\"caption\":\"H. Cemre G\u00fcnay\"},\"sameAs\":[\"http:\\\/\\\/192.168.34.155\\\/wordpress\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Dell VxRail \/ vSphere 8.0.310 Update - Advisory Report identified issues with BOSS Device - irgNET","description":"In a VxRail 8.0.300 deployment, I wanted to upgrade the appliance to the latest 8.0.310 after the initial cluster deployment, but I was confronted with a very strange phenomenon in the advisory report.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/","og_locale":"en_US","og_type":"article","og_title":"Dell VxRail \/ vSphere 8.0.310 Update - Advisory Report identified issues with BOSS Device - irgNET","og_description":"In a VxRail 8.0.300 deployment, I wanted to upgrade the appliance to the latest 8.0.310 after the initial cluster deployment, but I was confronted with a very strange phenomenon in the advisory report.","og_url":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/","og_site_name":"irgNET","article_published_time":"2024-10-23T14:57:02+00:00","article_modified_time":"2024-10-23T15:04:51+00:00","og_image":[{"url":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/wp-content\/uploads\/2023\/07\/picture6.webp","type":"","width":"","height":""}],"author":"H. Cemre G\u00fcnay","twitter_card":"summary_large_image","twitter_creator":"@irg_net","twitter_site":"@irg_net","twitter_misc":{"Written by":"H. Cemre G\u00fcnay","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/#article","isPartOf":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/"},"author":{"name":"H. Cemre G\u00fcnay","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#\/schema\/person\/71b46e79e8c12bdc8e610214a6621a66"},"headline":"Dell VxRail \/ vSphere 8.0.310 Update &#8211; Advisory Report identified issues with BOSS Device","datePublished":"2024-10-23T14:57:02+00:00","dateModified":"2024-10-23T15:04:51+00:00","mainEntityOfPage":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/"},"wordCount":577,"commentCount":0,"publisher":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#organization"},"image":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/#primaryimage"},"thumbnailUrl":"https:\/\/irg-net.com\/wp-content\/uploads\/2023\/07\/picture6.webp","articleSection":["Blog","Dell","Dell VxRail"],"inLanguage":"en","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/","url":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/","name":"Dell VxRail \/ vSphere 8.0.310 Update - Advisory Report identified issues with BOSS Device - irgNET","isPartOf":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/#primaryimage"},"image":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/#primaryimage"},"thumbnailUrl":"https:\/\/irg-net.com\/wp-content\/uploads\/2023\/07\/picture6.webp","datePublished":"2024-10-23T14:57:02+00:00","dateModified":"2024-10-23T15:04:51+00:00","description":"In a VxRail 8.0.300 deployment, I wanted to upgrade the appliance to the latest 8.0.310 after the initial cluster deployment, but I was confronted with a very strange phenomenon in the advisory report.","breadcrumb":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/#breadcrumb"},"inLanguage":"en","potentialAction":[{"@type":"ReadAction","target":["https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/"]}]},{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/#primaryimage","url":"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2023\/07\/picture6.webp?fit=304%2C266&ssl=1","contentUrl":"https:\/\/i0.wp.com\/irg-net.com\/wp-content\/uploads\/2023\/07\/picture6.webp?fit=304%2C266&ssl=1","width":304,"height":266},{"@type":"BreadcrumbList","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/index.php\/dell-vxrail-vsphere-8-0-310-update-advisory-report-identified-issues-with-boss-device\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/"},{"@type":"ListItem","position":2,"name":"Dell VxRail \/ vSphere 8.0.310 Update &#8211; Advisory Report identified issues with BOSS Device"}]},{"@type":"WebSite","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#website","url":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/","name":"irgNET","description":"a virtual Knowledge Base","publisher":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en"},{"@type":"Organization","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#organization","name":"irg-NET","url":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/","logo":{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#\/schema\/logo\/image\/","url":"https:\/\/i2.wp.com\/irg-net.com\/wp-content\/uploads\/2021\/06\/cropped-FINAL-Removed-Alpha.png?fit=2048%2C2048&ssl=1","contentUrl":"https:\/\/i2.wp.com\/irg-net.com\/wp-content\/uploads\/2021\/06\/cropped-FINAL-Removed-Alpha.png?fit=2048%2C2048&ssl=1","width":2048,"height":2048,"caption":"irg-NET"},"image":{"@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/irg_net","https:\/\/www.linkedin.com\/in\/h-cemre-g\u00fcnay-2b61601b4\/","https:\/\/www.youtube.com\/channel\/UC8GknhO5YMAkAoVxppu6aaQ"]},{"@type":"Person","@id":"https:\/\/irgnet-ga3w6nfbvw.live-website.com\/#\/schema\/person\/71b46e79e8c12bdc8e610214a6621a66","name":"H. Cemre G\u00fcnay","image":{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/secure.gravatar.com\/avatar\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/15f5d90a0ec651cb5003605e56e8ba104f93bc11230562284db56c845df9d54d?s=96&r=g","caption":"H. Cemre G\u00fcnay"},"sameAs":["http:\/\/192.168.34.155\/wordpress"]}]}},"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/posts\/12438","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/comments?post=12438"}],"version-history":[{"count":17,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/posts\/12438\/revisions"}],"predecessor-version":[{"id":12515,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/posts\/12438\/revisions\/12515"}],"wp:attachment":[{"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/media?parent=12438"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/categories?post=12438"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/irg-net.com\/index.php\/wp-json\/wp\/v2\/tags?post=12438"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}